ALLIANCE UU050E Especificaciones

Busca en linea o descarga Especificaciones para Secadoras de ropa eléctricas ALLIANCE UU050E. ALLIANCE UU050E Specifications Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 54
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
Programming
Tumble Dryer
OPL Electronic Control
Refer to Page 7 for Model Identification
Original Instructions
Keep These Instructions for Future Reference.
(If this machine changes ownership, this manual must accompany machine.)
www.alliancelaundry.com
Part No. 70444901ENR8
November 2014
Vista de pagina 0
1 2 3 4 5 6 ... 53 54

Indice de contenidos

Pagina 1 - Tumble Dryer

ProgrammingTumble DryerOPL Electronic ControlRefer to Page 7 for Model IdentificationOriginal InstructionsKeep These Instructions for Future Reference

Pagina 2

Gas Steam/Thermal Oil Electric35 Pound CHD35G2-CA035LCHD35G2-CA035NCHD35G2-CT035LCHD35G2-CT035NCHD35G2-CU035LCHD35G2-CU035NCK035NCK035RCT035RCU035RDR3

Pagina 3 - Front Matter

Gas Steam/Thermal Oil Electric45 PoundStackedCKT45NCKT45RCTT45LCTT45NCTT45RDR445G2-BAT45LDR445G2-BAT45NDR445G2-BKT45NDR445G2-BKT45RDR445G2-BTT45DDR445

Pagina 4 - Table of Contents

Gas Steam/Thermal Oil Electric50 Pound CA050LCA050NCK050NCT050LCT050NCU050LCU050NDR50G2-BA050LDR50G2-BA050NDR50G2-BK050NDR50G2-BT050DDR50G2-BT050LDR50

Pagina 5

Gas Steam/Thermal Oil Electric55 Pound CA055LCA055NCK055NCK055RCT055LCT055NCT055RCU055LCU055NCU055RDR55SG2-BA055LDR55SG2-BA055NDR55SG2-BK055NDR55SG2-B

Pagina 6

Gas Steam/Thermal Oil Electric75 Pound CA075LCA075NCK075NCK075RCT075LCT075NCT075RCU075LCU075NCU075RDR75G2-BA075LDR75G2-BA075NDR75G2-BK075NDR75G2-BK075

Pagina 7

Gas Steam/Thermal Oil Electric120 Pound CA120LCA120NCK120NCT120LCT120NCU120LCU120NDR120G2-BA120LDR120G2-BA120NDR120G2-BK120NDR120G2-BT120LDR120G2-BT12

Pagina 8

Gas Steam/Thermal Oil Electric200 Pound CA200LCA200NCT200LCT200NCU200LCU200NDR200G2-BA200LDR200G2-BA200NDR200G2-BT200LDR200G2-BT200NDR200G2-BU200LDR20

Pagina 9

Preliminary Information About the ControlThis control is an advanced, programmable computer that lets theowner control most machine features by pressi

Pagina 10 - Introduction

End of Cycle External Signal = Enabled (5 seconds)Clean Lint Screen Reminder = OffDisplay Limit Errors = DisabledManual Diagnostics = Enabled*Manual P

Pagina 11 - Part No. 70444901ENR8

Control Identification Operational KeypadThe control includes five keypads. These functions are availableto the operator and are intended to control a

Pagina 13

Keypad DescriptionSTART Press to start the selected cycle, select an option when in the menu or save a valuewhen editing a parameter.Status Indicator

Pagina 14

Time DryCycleDisplay6 DigitDisplay DescriptionDisplay 5 SAVE Custom Save Mode Dis-playTable 2MoistureDry CycleDisplay6 DigitDisplay DescriptionDisplay

Pagina 15

has been reached or the programmed cool down time expires,which ever happens first. End of Cycle ModeThe control enters End of Cycle Mode after the co

Pagina 16 - Nameplate Location

Machine Cycle Definition and OperationThere are 30 machine cycles that can be selected and run. Ma-chine cycles can be modified or made “unavailable”

Pagina 17 - Preliminary Information

Entering the Manual ModeFor programming, testing, and retrieving information from thecontrol, it is often necessary to enter the Manual Mode by follow

Pagina 18 - Entering Program Mode

Manual Mode: Enter by pressingStop ( ), then Back (ß), then Up (á) keypads“ Prog”Manual Programming“Audit ”Manual Read Audit“rESEt”Manual Reset“diA

Pagina 19 - Control Identification

Programming Control What Can Be Programmed?This feature allows the owner to program cycle parameters andother features by using the keypads. The contr

Pagina 20 - Operation Modes

OptionNumberOptionDisplay DescriptionDefaultValue Value Range7 CHHS3- Segment 3 - CHHS31 (Segment 3 Enable/Disable), CHHS32 (Seg-ment 3 Time), CHHS33

Pagina 21

OptionNumberOptionDisplay DescriptionDefaultValue Value Rangec tEnP 3 Global Medium Tempera-ture160°F[71°C]140°-160°F [60°-71°C](50, 75, 120, 170, 200

Pagina 22

OptionNumberOptionDisplay DescriptionDefaultValue Value Rangef rtC 6 Year - 0-99g rtC 7 Daylight Savings 1 1 (Enable), 0 (Disable)14 rAPdEn Manual Rap

Pagina 23 - Machine Cycle Operation

Front MatterWARNINGMachine installations must comply with minimumspecifications and requirements stated in the appli-cable Installation Manual, any a

Pagina 24 - Entering the Manual Mode

“CyCLE-”Cycle Programming“CHHEn”Cycle HH Enable Disable“CyCHH”Cycle to be programmed“CHHtyP”Cycle HH TypePress the “CHHnt”Cycle HH Material Type“CHHtP

Pagina 25 - Figure 6

“CHHS1-”Segment 1“CHHS2-”Segment 2 “CHHS11”Segment 1Enable/Disable“CHHS12”Segment 1 Time“CHHS13”Segment 1 Temperature“CHHS14”Segment 1 Auto DryTarget

Pagina 26 - Programming Control

“CHHS4-”Segment 4“CHHS5-”Segment 5 “CHHS41”Segment 4Enable/Disable“CHHS42”Segment 4Time“CHHS43”Segment 4 Temperature“CHHS44”Segment 4 Auto DryTarget L

Pagina 27

“CHHCd-”Cool Down“CHHr-”Reversing“CHHCd1”Cool DownTemperature“CHHCd2”Cool Down Time“CHHCd3”Cool Down Segment Reversing Enable/Disable“CHH r1”Cycle Rev

Pagina 28

“rEu-”Global ReversingParameters“tEnP-”Global Temperatures “rEu 1”Rotate Time“rEu 2”Stop Time“rEu 3”Advanced Reversing(On/off)“ tEnP 1”Global VeryLow

Pagina 29

“Aud 1 ”End of Cycle(On/off)“ Aud 2 ”End of CycleDuration“Aud 3 ”Keypad Feedback(On/off)“ESig 1”External SignalEnd of Cycle (on/off)“ESig 2”External S

Pagina 30 - Figure 7

“rtC 1”Minutes“rtC 2”Hours“rtC 3”Day“rtC 4”Date“rtC 5 ”Month“rtC 6”Year“rtC 7”Daylight Savings(on/off)“AIg”Auto Ignite Retry“diAgEn”Manual Diagnostics

Pagina 31 - Figure 8

Collecting Audit InformationThis feature allows the owner to retrieve audit information storedin the tumble dryer by pressing a sequence of pads on th

Pagina 32 - Figure 9

Manual ResetThis feature allows the owner to reset the tumble dryer control’sprogramming data to the factory default settings by pressing a se-quence

Pagina 33 - Figure 10

Custom SaveThis feature allows the owner to save a current cycle. For timedry cycles, the custom save will reprogram the cycle time to thetime that ha

Pagina 34 - Figure 11

Table of ContentsFront Matter... 3Introduction...

Pagina 35 - Figure 12

Testing Machine and Electronic Control Func-tionsThis feature allows the owner to run diagnostic tests on varioustumble dryer operations without servi

Pagina 36 - Figure 13

Diagnostic (Testing) Mode – Quick Reference ChartdAFS Airflow Switch TestdFAn Fan Motor TestddAnPr Damper Motor Test*drEuSE Reverse Motor Test*drotAt

Pagina 37 - Collecting Audit Information

TMB1374R_SVG“dSoft”Control Software Version Number TestPress the Up (á) or the Down (â) keypad to scroll through the Diagnostic Test options.“diAg””Di

Pagina 38 - Manual Reset

Diagnostic Test Descriptions Control Software Version Number TestThis option displays the control software version number. Tostart test, control must

Pagina 39 - Custom Save

DS8 DS7 DS6 DS5 DS4 DS3 DS2 DS1 DisplayOFF OFF OFF OFF ON OFF OFF OFF dSC008OFF OFF OFF ON OFF OFF OFF OFF dSC016OFF OFF ON OFF OFF OFF OFF OFF dSC032

Pagina 40 - How to Exit Testing Feature

To enter, press the Startkeypad. The display will show C HHH,with HHH the number corresponding to the machine capacity.Refer to Table 8 .Value Descrip

Pagina 41

NOTE: This test does not count towards the total ma-chine run time operation.To exit Damper Motor Test, press the Back keypad. The controlwill return

Pagina 42 - Figure 14

Production Test Cycle Quick Reference TableDisplay Test Mode CommentsS HH Software Version HH is the software version number.Ct HHH Control Type 2, 3,

Pagina 43 - Diagnostic Test Descriptions

Machine Errors PDA Communications ErrorThese errors may occur during communications. When an erroroccurs, the display indicates the error message on t

Pagina 44

closed for at least 5 seconds (it is flagged as an airflow switchbounce). If there are 5 airflow switch bounces within 5 minutesthe control will go to

Pagina 45

Entering the Manual Mode... 24How to Enter the Manual Mode...

Pagina 46 - Production Test Cycle

Error CodesFollowing is a list of possible error codes for an electronic con-trol. Errors beginning with EI refer to external device Infra-redcommunic

Pagina 47

Dis-play Description Cause/Corrective ActionE rot Rotation Sensor Error Check for broken or worn belts. Make sure machine is not over loaded and check

Pagina 48 - Machine Errors

Communication ModeThis mode is entered whenever the control is communicatingwith a PDA. Refer to PC and PDA Application User Instruc-tions. Infra-red

Pagina 49

Cycle ChartsCycle No. Cycle Name Cycle Type Material Type Reversing Temperature TargetMoistureor Time1 Towels Moisture Dry Cotton OFF 190°F [88°C] 1%2

Pagina 50 - Error Codes

27 5 Minute High Time Dry n/a OFF 190°F [88°C] 5 minutes28 5 Minute Med Time Dry n/a OFF 160°F [71°C] 5 minutes29 5 Minute Low Time Dry n/a OFF 140°F

Pagina 51

PDA Communications Error... 48Open Thermistor Error...

Pagina 52 - Communication Mode

Introduction Model IdentificationInformation in this manual is applicable to these tumble dryermodels:Gas Steam/Thermal Oil Electric25 Pound CHD25G2-C

Pagina 53 - Cycle Charts

Gas Steam/Thermal Oil Electric30 Pound CHD30G2-CA030LCHD30G2-CA030NCHD30G2-CT030LCHD30G2-CT030NCHD30G2-CU030LCHD30G2-CU030NCK030NCK030RCT030RCU030RDR3

Pagina 54

Gas Steam/Thermal Oil Electric30 PoundStackedCHD30STG2-CAT30LCHD30STG2-CAT30NCHD30STG2-CTT30LCHD30STG2-CTT30NCHD30STG2-CUT30LCHD30STG2-CUT30NCKT30NCKT

Comentarios a estos manuales

Sin comentarios